40249:THYROID STIMULATING HORMONE (TSH) WITH REFLEX TO FT4, IF INDICATED
Author PeaceHealth Laboratories
Print View Attached Docs: |
Methodology: |
Chemiluminescent Immunoassay (CLIA) |
Edit Date: |
6/11/2010 |
Performed: |
Daily |
Released: |
Same day as tested |
CPT Code: |
84443 / 84439 FT4, if reflexed |
Specimen Collection Details |
Collection: |
One 7.5 mL serum separator tube (SST). Also acceptable: One 4 mL green top tube (heparin) or one 4.5 mL light green plasma separator tube (PST). |
Handling: |
Centrifuge SST or PST and transport in original tube. Centrifuge green top tube, separate plasma from cells into a plastic vial. Refrigerate. Freeze if specimen cannot be assayed within 7 days. Allow no more than one freeze/thaw cycle. |
Stability: |
8 hours ambient, 7 days refrigerated, or 1 month frozen. |
Standard Volume: |
1 mL serum or plasma |
Minimum Volume: |
0.4 mL serum or plasma |
Transport: |
Refrigerated, or frozen on dry ice. |
Rejection Criteria: |
Use of EDTA tube. |
|
Male/Female ages 1 year to adult. |
0.61-1.27 ng/dL |
|
|
|